84 A-Class
Advanced Entry Calibration (continued)
Step Action Displayed Message Comment
16
a) Press the
ENTER
Key.
b) Using the
Key, set
the ‘Paper’ level to the value
determined in the previous
step.
c) Press the
ENTER
Key to set
the entry (indicated by the
*’) and advance the menu.
d) Repeat for the ‘Gap’ (or
Mark) value, and then the
‘Empty’ value.
PAPER SENSOR LEVEL
P* 198 G*000 E*000
GAP SENSOR LEVEL
P* 198 G*084 E*000
EMPTY SENSOR LEVEL
P* 198 G*084 E*014
!
!
-Or, for reflective media:
!
PAPER SENSOR LEVEL
P* 015 G*000 E*000
GAP SENSOR LEVEL
P* 015 G*181 E*000
EMPTY SENSOR LEVEL
P* 015 G*181 E*213
!
!
!
The selection will change to
indicate the item for entry.
17
Press the
ESC
Key to exit the
menu.
When prompted, press the
ENTER
Key
to save your
changes and return to Ready
Mode.
SAVE CHANGES
ENTER KEY = YES!
!
From ‘Ready’, press the
FEED
Key. The printer will advance
the next label to the TOF
position. If a problem occurs,
see the note below.
Note: If the Advanced Entry Calibration fails, try the following procedure:
Re-enter the Menu. Go to
Media Settings
Calibration
Advanced Entry
Sensor
Gain and lower the selected Gain Setting number by one (to desensitize the sensor). Select the new Gain
Setting, save the changes, and exit the menu. Test your media at the new setting. If necessary, repeat the
procedure until a usable media setting is obtained.